TM 5-6675-319-14
3-16.6 Replace Cabinet, Power, or Sink Switch(es).
MOS: 83FJ6, Reproduction Equipment Repairer
TOOLS: Flat Tip Screwdriver
SUPPLIES:
Switch(es)
Death or serious injury may occur from electrical shock unless power
cord is unplugged before servicing.
a.
Unplug sink power cord.
b . Remove switch cover.
c .
Loosen terminal screws; tag and disconnect wires from defective switch.
d .
Reconnect wiring to new switch and tighten terminal screws.
e.
Install new switch and tighten retaining screws.
f . R e i n s t a l l s w i t c h c o v e r .
g .
Plug in sink power cord.
3-38