TM 5-6675-319-14
3 - 2 .3
Equipment Data.
Dimensions
O v e r a l l
Refrigeration Cabinet
S i n k
Power Requirements
Thermostat Settings
Cabinet
R e f r i g e r a nt
Compressor Motor Horsepower
Length 80 in. (203.2 cm)
Width 35 in. (88.9 cm)
Height 46 in. (116.8 cm)
Length 28 in. (71.1 cm)
Width 29 in. (73.7 cm)
Height 27 in. (68.6 cm)
Length 75 in. (190.5 cm)
Width 26 in. (66.0 cm)
D e p t h 3 - 7 / 8 i n . ( 9 . 8 c m)
115 V, 60Hz, 16 amps
68°F (20°C) ±2° F (±l° C)
60°F (15.5°C)
Freon R-12
1/2 hp
3-3. TECHNICAL PRINCIPLES OF OPERATION.
The purpose of the processing sink is to
p r o v i d e a t e m p e r a t u r e - c o n t r o l l e d m e d i u m f o r p h o t o l i t h o g r a p h i c c h e m i s t r y . I t i s
comprised of:
Refrigeration System
Recycling System
Heating System
E l e c t r i c a l S y s t e m
3-3