Table 1-5. DIRECT/GENERAL SUPPORT TROUBLESHOOTING
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1.
PERSONNEL/CARGO DOORS DO NOT CLOSE COMPLETELY.
Step 1.
C h e c k t h a t l a t c h r o l l e r s r o t a t e f r e e l y.
Replace latches (paragraph 1-20.2).
Step 2.
Check to see if latch rods are bent.
Replace latch rods (paragraph 1-20.2).
Step 3.
Check to see if door gasket is torn or broken.
Replace door gasket (paragraph 1-20.3)
2.
PERSONNEL/CARGO DOORS DO NOT LATCH PROPERLY.
Check door latch for missing or damaged components.
Replace door latch (paragraph 1-20.2)
3.
AIR OR WATER ENTERS SECTION AROUND DOOR.
Check to see if door gasket if worn or broken.
Replace door gasket (paragraph 1-20.3)
1-89