TM 5-6675-318-14
NOTE
The program will test pens one through four.
If it is desired to test
all eight pens, modify the test program lines 60 and 63, as follows:
From: 60:
plt 29,6,1;pen #4;lbl "DIVISION"
T o : 60: p l t 2 9 , 6 ; p e n # 4 ; l b l ` D I V I S I O N " ; g t o 8 1
From: 63:
prt "9872A PLOT", " C O M P L E T E " ; spc 2;wrt S,"DF";end
T o : 63:
prt "9872A PLOT",''COMPLETE"
Add the following lines at the end of the test program:
p l t 4,3,1;pen #1;lbl "PEN #1"
p l t 4,2,1;pen #2;lbl "PEN #2"
p l t 4,1,1;pen #3;lbl "PEN #3"
p l t 4,0,1;pen #4;lbl "PEN #4"
p l t 29,3,1;pen #5;lbl "PEN #5"
p l t 29,2,1;pen #6;lbl "PEN #6"
p l t 29,1,1;pen #7;lbl "PEN #7"
p l t 29,0,1;pen #8;lbl "PEN #8"
g t o 69
To make above change 1df14, make changes to lines 60 and 63, and add
additional lines to rcf 14 program.
(1) Check that LINE power switch is set to off (0).
(2) Check that voltage switches are set for 120 V ac.
(4) Check that logic ADDRESS switches are set to 5 (10100).
Press LINE power switch on (0).
(6) Mount paper:
( a ) Press CHART LOAD switch.
(Pen should go to upper right corner.)
(b) Raise paper stop by pressing down upper portion with screwdriver
or other pointed object.