TM 5-6675-316-14
Table 8-3. DIRECT/GENERAL SUPPORT TROUBLESHOOTING - Cont
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
8. AMBER OPERATE PILOT LIGHT AND MOTOR SWITCH ARE ON, BUT ROLLERS DO NOT TURN
- Cont
Step 2.
Turn wax coater ON.
When wax has melted, raise coating carriage and
check tightness of drive belt.
(a) If belt tension is correct, proceed to step 3.
(b) If belt is broken or defective, replace drive belt. If
loose, tighten drive belt (paragraph 8-20.8).
Step 3.
Check pressure roller gear for damage or looseness.
Replace faulty pressure roller gear (paragraph 8-20.11).
8-46