TM 5-6675-316-14
Section II OPERATOR MAINTENANCE
8-8. LUBRICATION INSTRUCTIONS.
This equipment does not require lubrication.
8-9. TROUBLESHOOTING PROCEDURES.
a.
The table lists the common malfunctions which may occur during the operation
or maintenance of the adhesive wax coater, or its components.
You should perform
the test/inspections and corrective actions in the order listed.
b. This manual cannot list all malfunctions that may occur, nor all test or
inspections and corrective actions.
If a malfunction is not listed or is not
corrected by listed corrective actions, notify your supervisor.
Table 8-2.
TROUBLESHOOTING
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1.
WAX COATER DOES NOT WORK; WAX REMAINS COLD.
Step 1.
Check to see if ac power cord is plugged into wall outlet.
(a) If cord is plugged in, proceed to step 2.
(b) Plug cord into ac electrical outlet.
Step 2.
Check to see if outlet circuit breaker is tripped.
(a) If circuit breaker is on, refer to organizational
maintenance.
(b) Reset circuit breaker.
2. WAX COATING APPEARS FLAT AND DULL.
Step 1.
Check wax level.
(a) If wax level is correct, proceed to step 2.
(b) Break up new wax into small cubes. When OPERATE pilot light
is lit, place wax cubes into tray until wax is at operating
level.
8-27