Table 2-3. TROUBLESHOOTING - Cont
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
2.
LINES ARE NOT PROPERLY JUSTIFIED - Cont
Step 2.
Check that corrections are entered on line after entering reverse
carriage function.
(a) If corrections entered properly, proceed to step 3.
(b) Make all corrections on line before entering reverse
carriage function.
(c) Cancel entire line and retype it correctly.
Check if justified space was attempted to be used within reverse
Step 3.
carriage sequence.
(a) If entries were properly made, proceed to step 4.
(b) If two or more words are typed, use fixed space between them.
Fixed space of six units is desirable word space.
Check for runover left on typing line.
Step 4.
Clear last line and enter end-of-job command.
PROLONGED BEEP SOUNDS DO NOT STOP.
3.
Check to see if internal composing machine temperature is too high for
reliable operation<
(a) End job within one minute and turn off composing machine.
(b) Notify direct/general support maintenance.
4. UNWANTED CHARACTERS ARE APPEARING ON DISPLAY AND RANDOM COMMANDS ARE BEING
EXECUTED.
Check for unstable 120 V ac.
Notify direct/general support maintenance.
2-135