TM 5-6675-315-14
f.
Tag and disconnect wires.
WARNING
Motor is heavy and awkward to handle. Do not drop. Use lifting bar and two personnel to raise
or move motor.
g.
Remove defective pump motor assembly and relief valve. Remove relief valve from old motor and install on
new motor. Insert new O-ring and sealing washer.
h.
Install new pump motor.
i.
Bolt motor assembly to frame.
j.
Reconnect wiring.
k.
Refill hydraulic system.
l.
Turn on circuit breaker.
m.
Turn main power switch on and cycle ram to determine if hydraulic system leaks.
n.
Reinstall panels and feed tray.
2-153