TM 5-6675-315-14
f.
Remove lead wire seal.
g.
Remove pressure-activated switch wiring cover.
h.
Tag and disconnect wires.
i.
Disconnect pipe and unions from switch; then remove defective switch.
j.
Replace switch, connect hydraulic piping and wires.
k.
Refill hydraulic system.
l.
Adjust switch (paragraph 2-16.20).
m.
Reinstall panels and feed tray.
n.
Turn on circuit breaker.
o.
Turn on main power switch.
2-151