TM 5-6675-315-14
Table 2-5. ORGANIZATIONAL TROUBLESHOOTING - Cont
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
2.
CUTTER MECHANISM WILL RUN IN REVERSE BUT NOT FORWARD - Cont
Step 4. Check the continuity of cutter reverse relay SR.
(a)
If present, proceed to step 5.
(b)
If not present, replace cutter reverse relay (paragraph 2-16.10).
Step 5. Check control relay SS for continuity.
(a)
If present, proceed to step 6.
(b)
If not present, replace control relay (paragraph 2-16.10).
2-57