CAUTION
Glass surface must be handled with care to avoid chipping or breaking.
d.
e.
f.
g.
h.
i.
j.
k.
l.
m.
n.
Remove glass surface and set aside.
Remove screws and back cover panel.
Remove screws and defective ballast transformer.
Disconnect and tag wires from ballast transformer.
Connect wiring on new ballast transformer and remove tags.
Install new ballast transformer and secure with screws.
Reinstall back cover panel and secure with screws.
Reinstall glass surface.
Turn clips 90° to secure glass surface.
Reinstall screws on clips. Tighten all screws.
Plug in power cord and turn power switch ON.
2-16.4 Remove/Install Mounting Bracket.
MOS:
83FJ6, Reproduction Equipment Repairer
TOOLS:
1/4 in. Socket Set/Cross Tip Screwdriver
SUPPLIES:
Mounting Bracket
a. Remove portable tracing/scribing board from mounting bracket.