WARNING
WARNING
TM 5-6675-302-14&P
b. Disassembly, Replacement and Reassembly.
c. Installation.
(1) Refer to figure 5-11 and disassemble the
(1) Install the sleeve (para 5-15).
bracket (4 thru 7).
(2) Install the target base (para 5-14).
(2) Replace defective parts with serviceable
(3) Install the target level assembly (para 5-13).
parts.
(4) Install the target frame (para 5-12).
(3) Refer to figure 5-11 and reassemble the
bracket (4 thru 7).
Section V. REPAIR OF TARGET ASSEMBLY (MODEL USATS-79)
5-17. General. On model USATS-79 the target
assembly consists of a target plate and a target
plate carrier incorporating a target level and three
feet for clamping to the tribrach. Refer to section
IV for repair of the target assembly for model
242406.
5-18. Target Plate.
a. Removal.
(1) Refer to paragraph 4-9 and remove the
target assembly from the tribrach.
(2) Refer to figure 5-14 and remove the target
plate from the target plate carrier.
b. Disassembly. Refer to figure 5-15 and
disassemble the target plate.
c. Cleaning Inspection and Repair.
Clean parts in a well-ventilated area.
Avoid inhalation of solvent fumes and
prolonged exposure of skin to cleaning
solvent. Wash exposed skin thoroughly.
Dry cleaning solvent (Fed. Spec.
P-D-680) used to clean parts is potential-
ly dangerous to personnel and property.
Do not use near open flame or excessive
heat. Flash point of solvent 100F to
138F (38C to 59C).
(1) Clean all metal parts with cleaning solvent
and dry thoroughly. Clean mask with lens tissue or
lens cloth.
(2) Inspect cover plate, target frame and
plunger for cracks, dents, breaks and burrs.
inspect spring for cracks. Inspect all threaded
parts for worn or damaged threads.
(3) Remove all burrs and minor dents.
(4) Replace all defective parts that cannot be
repaired.
d. Reassembly. Refer to figure 5-15 and
reassemble the target plate.
e. Installation.
(1) Refer to figure 5-14 and install the target
plate on the target plate carrier.
(2) Refer to paragraph 4-9 and install the
target assembly on the tribrach.
5-19. Target Plate Carrier
a. Removal and Disassembly.
(1) Remove the target assembly, paragraph
5-18.
(2) Refer to figure 5-16 and disassemble the
target plate carrier.
b. Cleaning, Inspection and Repau.
Clean parts in a well-ventilated area.
Avoid inhalation of solvent fumes and
prolonged exposure of skin to cleaning
solvent. Wash exposed skin thoroughly.
Dry cleaning
solvent (Fed. Spec.
P-D-680) used to clean parts is potential
ly dangerous to personnel and property.
Do not use near open flame or excessive
heat. Flash point of solvent is 100F to
138F (38C to 59C).
(1) Clean all metal parts with cleaning solvent
and dry thoroughly. Wipe target level with lens
tissue or lens cloth.
(2) Inspect level housing, carrier housing and
centering flange for dents, cracks, breaks and
burrs. Inspect springs for cracks. Inspect target
level and plastic tube for cracks and scratches.
(3) Remove all burs and minor dents.
(4) Replace all defective parts that cannot be
repaired.
5-15