Figure 2-127.
TM 5-3610-286-20
2-57.
Gripper System Assembly (cont).
d. Adjust.
(1) Individual gripper pressure, (figure 2-127)
(a)
(b)
(c)
Place a 0.7 mm feeler gage (1) between gripper bar (2) and lever (3) on an individual
gripper.
NOTE
Some presses require more or less pressure. Size of gap to be used is
stamped on right side of gripper bar.
Loosen socket-head screw (4).
Adjust each individual gripper by placing tissue paper under the gripper and tightening
socket-head screw (4) until paper can just be pulled out.
2-292