TM 5-3610-285-14
b.
Remove knob from temperature control.
c.
Remove screws from temperature control housing.
NOTE
Note location of temperature control capillary tube.
d.
Remove housing from control bracket.
e.
Remove screws securing temperature control to housing and discard defective temperature control.
f.
Install new temperature control in housing and secure with screws.
g.
Replace housing on control bracket and secure with screws.
CAUTION
Capillary tube is fragile and should be handled with care to avoid damage.
h.
Place capillary tube in position previously noted.
i.
Replace temperature control knob and set to OFF.
j.
Plug in power cord.
k.
Turn on temperature control and set to desired temperature.
10-32