TM 5-3610-285-14
Table 8-2. TROUBLESHOOTING - Cont
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. ILLUMINATION UNEVEN Cont
Step 2. Check to see if either fluorescent lamp is partially lighted or is dark.
(a)
If fluorescent lamp is partially lighted, replace fluorescent lamp (paragraph 8-10.2).
(b)
If illumination is still uneven, proceed to step 3.
Step 3. Check for defective lamp starter.
(a)
If lamp starter is not defective, check with supervisor.
(b)
If lamp starter is defective, replace defective starter (paragraph 8-10.3).
8-10. MAINTENANCE PROCEDURES.
a.
This section contains instructions covering operator maintenance functions for the portable tracing/scribing
board. Personnel required are listed only if the task requires more than one.
b.
After completing each maintenance procedure, perform operational check to be sure that equipment is properly
functioning.
INDEX
PROCEDURE
PARAGRAPH
Clean Reflector ...............................................................................................................
8-10.1
Replace Fluorescent Lamp...............................................................................................
8-10.2
Replace Starter ...............................................................................................................
8-10.3
Replace Glass Surface ....................................................................................................
8-10.4