TM 5-3610-285-14
Table 5-5. ORGANIZATIONAL TROUBLESHOOTING - Cont
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
6.
REPLENISHER PUMP DOES NOT ACTIVATE WHEN FILM IS FED. MAIN DRIVE SWITCH IS ON AND REPL
PUMPS SWITCH IS IN AUTO Cont
Step 10. Check voltage between terminal block connector 2-13 and ground.
(a)
If 120 V ac is present, proceed to step 11.
(b)
If voltage is not present, refer to higher level of maintenance.
Step 11. With detector switches actuated, check voltage between terminal block connectors 2-13 and wire 70 on
relay U5.
(a)
If voltage is not present, proceed to step 12.
(b)
If 120 V ac is present, replace relay U5 (paragraph 5-16. 26).
Step 12. With detector switches actuated and REPL PUMPS switch in AUTO, check voltage between terminal
block connector 2-10 and ground.
(a)
If 120 V ac is present, refer to direct support/general support maintenance for repair of replenisher
pump.
(b)
If voltage is not present, replace REPL PUMPS switch (paragraph 5-16. 5).
5-121