TM 5-3610-285-14
Table 5-5. ORGANIZATIONAL TROUBLESHOOTING - Cont
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
6.
REPLENISHER PUMP DOES NOT ACTIVATE WHEN FILM IS FED. MAIN DRIVE SWITCH IS ON AND REPL
PUMPS SWITCH IS IN AUTO - Cont
WARNING
Death or serious injury may occur from electrical shock unless power is turned off before servicing.
Step 1. Check film detector crossover switches.
(a)
If gap is .020 to .025 in (.5 to .6 mm), proceed to step 2.
(b)
If gap is not correct, adjust detector crossover switches (Table 5-3, Item 1).
Step 2. Check for defective fuse FU1.
(a)
If fuse is good, proceed to step 3.
(b)
If fuse is open, replace fuse (paragraph 5-16.1)
Step 3. Check for defective fuse FU2.
(a)
If fuse is good, proceed to step 4.
(b)
If fuse is open, replace fuse (paragraph 5-16.1).
5-118