TM 5-3610-285-14
Table 5-3. OGANIZATIONAL PEVENTIVE MAINTENANCE CHECKS AND SERVICES - Cont
B - Before
W - Weekly
AN - Annually
(Number) - Hundreds of Hours
D - During
M - Monthly
S - Semiannually
A - After
Q - Quarterly
BI - Biennially
ITEM TO BE INSPECTED
IN
ITEM
TER-
PROCEDURE
NO.
VAL
FILM PROCESSOR - Cont
2
S
Adjust Developer Temperature - Cont
NOTE
Allow sufficient time for solution temperature to
stabilize after adjustment, before taking readings.
5.
Remove fixer and developer pump access cover.
6.
Remove plastic plug from developer thermostat
cover. A small adjustment will change
temperature several degrees, so move screw
only about 1/8 turn at a time.
7.
Using a small, nonmetallic screwdriver, turn
potentiometer adjusting screw right to raise
developer temperature and left to lower
developer temperature.
8.
Remove thermometer from developer tank.
9.
Reinstall plug and covers.
5-84