TM 5-3610-285-14
e.
lag and disconnect wires for photo detector assembly.
f.
Tag and disconnect wires for glass frame proximity switch from terminal block.
g.
Tag and disconnect vacuum hoses from vacuum gages.
h.
Carefully set control panel back onto top retaining lip.
i.
Remove two screws and lower cabinet panel.
j.
Tag and disconnect plug connector for control panel.
k.
Remove control panel from flip-top platemaker and place on a convenient work surface.
l.
Carefully reinstall control panel onto top retaining lip.
m.
Reconnect plug connector for control panel.
n.
Reinstall lower cabinet panel.
o.
Carefully lift control panel from retaining lip to gain access to wiring.
p.
Reconnect vacuum hoses to vacuum gages.
q.
Reconnect wires for glass frame proximity switch to terminal block.
r.
Reconnect wires-for photo detector assembly.
s.
Carefully lift control panel onto its mount.
t.
Reinstall mounting screws for control panel.
u.
Rotate glass frame into horizontal position and lock into place with frame release knob.
v.
Turn on power panel circuit breaker.
2-73