TM 5-3610-285-14
WARNING
Voltages that are capable of causing death may be stored in capacitors after power is
removed. Ground and discharge capacitors to zero volts before disconnecting capacitor
leads. Personal injury or death may occur from failure to do so.
c.
Tag and disconnect wires from capacitors. Capacitor bottom connector is the negative connector.
d.
Remove nuts and washers from studs for holddown brackets that hold top two capacitors.
NOTE
If one of the top two capacitors is being replaced, proceed to step f.
e.
Remove nuts and washers from studs for holddown brackets that hold bottom two capacitors.
f.
Remove defective capacitor from housing.
NOTE
If one of the top two capacitors were replaced, proceed to step h.
g.
Install new capacitor into housing and reinstall holddown brackets for capacitors.
h.
Install new capacitors into housing and reinstall holddown brackets for top capacitors.
i.
Reconnect wires to capacitors.
j.
Reinstall lower cabinet panel.
k.
Turn on power panel circuit breaker.
2-59