TM 5-3610-285-14
c.
Remove main power contactor cover.
d.
Tag and disconnect wires from main power contactor.
e.
Remove two screws on bracket and remove bracket with contactor attached.
f.
Remove insulator and defective main power contactor from mounting bracket.
g.
Install new main power contactor and insulator onto mounting bracket.
h.
Reinstall contactor and mounting bracket into housing.
i.
Reconnect wire to new contactor.
j.
Reinstall main power contactor cover.
k.
Rotate glass frame into horizontal position and lock into place with frame release knob.
l.
Turn on power panel circuit breaker.
2-61