TM 5-3610-285-14
Table 2-4. ORGANIZATIONAL TROUBLESHOOTING - Cont
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
9.
EXPOSURE LAMP DOES NOT OPERATE IN ANY MODE - Cont
(b)
Connect other meter lead to wire on rear of capacitor (wire number 5) on the autoformer relay
(K2) and check for continuity.
(1)
If continuity is present, replace autoformer relay (K2) (paragraph 2-16.19).
(2)
If continuity is not present, refer to direct/general support maintenance for replacement
of overtemperature switch.
10.
VACUUM PUMP DOES NOT BUILD UP CORRECT VACUUM.
Step 1.
Check all vacuum hoses and connections for air leaks.
(a)
If no air leaks are found, proceed to step 2.
(b)
Correct cause of air leak.
2-51