TM 5-3610-285-14
Table 2-4. ORGANIZATIONAL TROUBLESHOOTING - Cont
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
9.
EXPOSURE LAMP DOES NOT OPERATE IN ANY MODE.
Step 1.
Check LEDs 3 and 4 on 3kW power supply board as follows:
(a)
Turn off power panel circuit breaker.
(b)
Remove two screws and right side louvered panel.
(c)
Position panel so that fans can operate when power is applied.
(d)
Turn on power panel circuit breaker.
2-47