TM 5-3610-285-14
Table 2-4. ORGANIZATIONAL TROUBLESHOOTING
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1.
FLIP-TOP PLATEMAKER DOES NOT ENERGIZE.
Step 1.
Check for 220 V ac input to flip-top platemaker at utility outlet box.
(a)
If voltage is present, proceed to step 2.
(b)
If no voltage is present, proceed to organizational troubleshooting in chapter 1.
Step 2.
Check for 220 V ac between fuses Fl and F2 on relay panel.
NOTE
It will be necessary to override lower cabinet door proximity switch before voltage
readings can be obtained. Remove magnet from door, and place it on switch.
(a)
If voltage is present, proceed to step 3.
(b)
If voltage is not present,, proceed to step 4.
Step 3.
Check output of master circuit breaker in platemaker.
(a)
If voltage is present, replace master power switch (paragraph 2-16.12).
(b)
If voltage is not present, replace master circuit breaker (paragraph 2-16.16).
2-43