TM 5-3610-285-14
s. When exposure is complete, pull out on frame release knob and flip glass frame over so that second vacuum
frame faces exposure lamp and lock in place.
t. If a second plate is being produced, perform steps o - q before continuing.
u. Press off vacuum pump switch for newly exposed plate.
v. Open bleed valve to bleed off vacuum for vacuum frame on top.
w. Unlock left- and right-hand latches and lift glass frame until the two lift arms take hold and open the frame
completely.
x. Carefully remove and separate flat from plate. Store flat in a safe place.
y. Process newly exposed plate.
z. If more plates are to be processed, repeat steps c - m to prepare vacuum frame.
aa. If second plate is being processed, repeat steps s - x to finish second plate.
ab. If all plate processing is complete, press off master POWER switch.
2-23