TM 5-3610-259-14
e.
Remove Y hose connector from backside of vacuum gage.
f. Remove two mounting nuts from vacuum gage and remove defective vacuum
gage, with bracket and y hose connector, through top of control panel.
9.
Install new vacuum gage through top of control panel and place mounting
bracket around gage so that mounting studs fit through the holes.
Attach in place with mounting nuts.
Be sure gage is properly centered
on panel.
h.
Reinstall Y hose connector on back side of vacuum gage.
i.
Carefully lift control panel onto its mount.
j.
Reinstall mounting screws for control panel.
k. Rotate glass frame into horizontal position and lock into place with
frame release knob.
l.
Turn on power panel circuit breaker.
2-75