TM 5-3610-259-14
Table 2-2.
TROUBLESHOOTING - Cont
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
3.
HALATION OCCURS: APPEARS AS DOT SPREADING; COPY ENLARGED AT EDGES; SHADOWS
ON TYPE - Cent
Step 5.
Check that the proper units of lights were entered.
(a) If light units were entered correctly, proceed to step 6.
(b) Enter correct units of light.
Step 6.
Adjust photodetector assembly (paragraph 2-10.2).
If problem persists, notify your supervisor.
4. BROKEN IMAGES.
Step 1.
Step 2.
Step 3.
Check stripped flat for tape or opaquing solution covering portion
of image that is broken.
(a) If stripped flat is correctly prepared, proceed to step 2.
(b) Correctly prepare flat.
Check that glass frame is clean.
(a) If glass frame is clean, proceed to step 3.
(b) Clean glass frame.
Check exposure with sensitivity guide.
(a) If exposure correct, problem may be due to flat being dirty.
Clean flat.
(b) Reset exposure controls.
2-33