TM 5-3610-258-14
Table 5-4. DIRECT/GENERAL SUPPORT TROUBLESHOOTING - Cont
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
5.
WATER LEVEL GAGE DOES NOT INDICATE.
Check water level in tank.
Replace water level gage (paragraph 5-20.4).
6.
WATER IS NOT AT CORRECT TEMPERATURE.
Step 1.
Check for the presence of 208 V ac at immersion heater input.
a.
If voltage is not present, proceed to step 2.
b.
If voltage is present, replace the immersion heater (paragraph 5-20.5).
Step 2.
Check for the presence of 208 V ac at input to magnetic contactor.
If voltage is present, replace the magnetic contactor (paragraph 5-20.6).
5-20.
MAINTENANCE PROCEDURES.
a.
This section contains instructions covering direct/general support maintenance functions for the sink.
Personnel required are listed only if the task requires more than one.
b.
After completing each maintenance procedure, perform operational check to be sure that equipment is
properly functioning.
5-48