TM 5-3610-257-14
5-10.
OPERATORS MAINTENANCE PROCEDURES.
a.
This section contains instructions covering operator maintenance functions for the sink. Personnel required are
listed only if the task requires more than one.
b.
After completing each maintenance procedure, perform operational check to be sure that equipment is properly
functioning.
INDEX
PROCEDURE
PARAGRAPH
Adjust Sink Thermostat .............................................................................................................................5-10.1
Adjust Cabinet Thermostat ...................................................................................................................... 5-10.2
5-10.1. Adjust Sink Thermostat.
MOS:
83E, Photo and Layout Specialist
TOOLS:
Hex Head Key Wrench Set
a.
Unlatch and remove front cover.
b.
Loosen recessed lockscrew.
c.
Rotate dial until desired temperature corresponds with pointer reading.
d.
Tighten lockscrew.
e.
Reinstall front cover and secure with latch.
5-20