TM 5-3610-257-14
4-16.8. Replace Transformer.
MOS: 35E, Special Electronic Devices Repairer
TOOLS: Flat Tip Screwdriver
Soldering Iron
SUPPLIES:
Transformer
Solder
WARNING
Death or serious injury may occur from electrical shock unless power cord is unplugged before
servicing.
a.
Remove densitometer (paragraph 4-20.1).
b.
Remove chassis cover.
c.
Tag and unsolder wires from defective transformer.
d.
Remove transformer from chassis.
e.
Install new transformer.
f.
Solder wires and remove tags.
g.
Install chassis cover.
h.
Install densitometer (paragraph 4-20.1).