TM 5-3610-253-14
Table 5-23. DIRECT/GENERAL SUPPORT TROUBLESHOOTING - Cont
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
5. ERROR MESSAGE 84.
While locking valve (M1) Solenoid (Y315) is switched off, voltage of +42 V
is missing on control line for locking valve.
Check +42 V supply voltage to locking valve at connector CU 6,
Step 1.
pin 9.
(a) If +42 V is present, proceed to step 4.
(b) If + 42 V is not present, proceed to step 2.