(2) Connect air hose to valve.
(3) Inflate each mount until top of diaphragm is level as shown.
(4) Reinstall valve caps.
WARNING
Death or serious injury may occur if power cable is disconnected while
power is on.
f. Turn equipment switches off.
Turn main circuit breaker off.
9.
h. Turn safety switch off.
Have power cable disconnected at power supply end. Then disconnect power
i.
cable from receptacle. Put cable in storage box on trailer chassis.
Turn emergency light switch off.
j.
k. Disconnect telephone cables from power entry panel.
CAUTION
To prevent loss of rod or thread damage, do not allow ground rod to
rotate and unscrew when removing the slide hammer rod.
1. Remove ground rod with slide hammer, and put ground rods, couplings, and
slide hammer' inside section. Clean threads on each ground rod before storing.
NOTE
Be certain exhaust fan and air vent covers are securely closed.
1-35