TM 5-3610-253-14
Table 1-1.
OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES - Cont
VAN BODY - Cont
Inspect Exterior - Cont
Visually inspect ground connections to be sure
8.
Ground
ground cable is connected to terminal lug and
connec-
ground rod. If necessary, clean:
tions are
broken or
missing.
WARNING
Electrical shock hazard. Power cable must
be de-energized before servicing entry panel
connections. Death can result from failure to
observe these safety precautions.
a.
Turn power off to cable. Disconnect from power
source.
b. Disconnect ground lug from ground rod.
c.
Clean lug, cable end, and rod with wire brush.
d.
Reconnect ground cable lug to rod.
e.
Disconnect ground cable end from entry panel.
f. Clean terminal and cable end with wire brush.
Reconnect ground cable to entry panel.
g.
h.
Reconnect cable to power source. Turn power on.
Inspect boarding ladders for:
9.
Steps are
B
broken or
a.
Secure attachment of handrails.
will not
lock in
b. Steps not broken.
place.
c.
Locking pins in place.
1-17