TM 5-3610-252-14
b. Drive split pin out and remove activator arm.
c.
Unscrew plunger body and remove.
d. Disassemble plunger body by removing copper seal, O-ring, plunger,
plunger O-ring, spring, and ball.
e.
Wipe all parts clean with lightly oiled cheesecloth.
f.
Install new O-ring in machined groove of plunger body. Reinstall copper
seal.
g.
Install new O-ring on plunger.
Insert plunger spring and plunger into
hex end of plunger body.
h.
Insert ball into plunger body from unthreaded end.
i.
Screw plunger body into hydraulic unit.
j.
Reinstall activator arm and split pin into hydraulic unit and attach
chain connector.
k. Fill with hydraulic fluid and bleed air from system.
2-27