TM 5-2330-306-14
2. Remove four nuts and washers.
3. Remove bottom plate.
4.
Remove two U-bolts (4).
5.
Install two new U-bolts.
6. Install bottom plate and secure to U-bolt with four nuts and
washers.
Alternately torque nuts until 700-750 ft lbs is achieved.
7. Retract chassis leveling jacks.
4.4.1.18 REPLACE MOISTURE EJECTOR.
TOOLS: Adjustable Wrench
SUPPLIES: Thread Sealant (TFL)
Automatic Moisture Ejector
1. Pull on ejector lanyard until system is depressurized.
2. Remove ring connecting ejector lever to lanyard.
3. Unscrew ejector housing from bottom of tank.
C A U T I O N
DO NOT ALLOW THREAD SEALANT
TO CONTAMINATE AIR SYSTEM.
4.
Spread some thread sealant on threads of new ejector housing.
Clean old thread sealant from tank threads.
5. Screw new ejector into bottom of tank. Tighten securely.
6. Attach ring and lanyard cable to ejector.
4-39