TB 1-4920-443-35
AEDATS IV T53/T55/T63 ALIGNMENT WORKSHEET
(d) PT-101,
0-50 in-hg abs, Barometer
1 Locate PT-101 on the bell mouth and barometer panel in cabinet 10. Connect the low
pressure calibrator directly to the transducer. Apply following pressures and record the
results. (2.036)
2 Do not zero barometer only set span
Vertical Scale bottom row 9
5SE01313-22
AEDATS 4
Actual
AEDATS 4
6SE00950-28
Pressure
Vertical Scale Channel name
Pressure
(*)
(in-hg abs)
(*)
psi
+/- .05 psi
+/- 0.25 psi
T53 Baro
+3
____________
____________
____________
T55 Baro
Vent
____________
____________
____________
T63 Baro
-3
____________
____________
____________
L714 Baro
R-cal
____________
Transducer: T40
Hardware Name: HL21
(e) PT-102,
0-50 in-h2o, B/M Static Pressure #1
1 Locate PT-102 on the bell mouth and barometer panel in cabinet 10. Connect the low
pressure calibrator directly to the transducer. Apply following pressures and record the
results.
Vertical Scale bottom row 6
5SE01313-19
AEDATS 4
Actual
AEDATS 4
6SE00950-29
Pressure
Vertical Scale Channel name
Pressure
(*)
(in-h2o)
(*)
psi
+/- .25 psi
+/- .25 psi
T53 Ps11
0
____________
____________
____________
T55 Ps11
10
____________
____________
____________
T63 Ps11
20
____________
____________
____________
L714 PSBM1
30
____________
____________
____________
40
____________
____________
____________
50
____________
____________
____________
R-cal
____________
Transducer: T37
Hardware Name: HL18
187