TB 1-4920-443-35
AEDATS IV T53/T55/T63 ALIGNMENT WORKSHEET
(f) PT-103,
0-50 in-h2o, B/M Static Pressure #2
1 Locate PT-103 on the bell mouth and barometer panel in cabinet 10. Connect the low
pressure calibrator directly to the transducer. Apply following pressures and record the
results.
Vertical Scale bottom row 7
5SE01313-19
AEDATS 4
Actual
AEDATS 4
6SE00950-29
Pressure
Vertical Scale Channel name
Pressure
(*)
(in-h2o)
(*)
psi
+/- .25 psi
+/- .25 psi
T53 Ps12
0
____________
____________
____________
T55 Ps12
10
____________
____________
____________
T63 Ps12
20
____________
____________
____________
L714 PSBM2
30
____________
____________
____________
40
____________
____________
____________
50
____________
____________
____________
R-cal
____________
Transducer: T38
Hardware Name: HL19
(c) PT-104,
0-50 in-h2o, B/M Total Pressure
(a) Locate PT-104 on the bell mouth and barometer panel in cabinet 10. Connect the low
pressure calibrator directly to the transducer. Apply following pressures and record the
results.
Vertical Scale bottom row 8
5SE01313-19
AEDATS 4
Actual
AEDATS 4
6SE00950-29
Pressure
Vertical Scale Channel name
Pressure
(*)
(in-h2o)
(*)
psi
+/- .25 psi
+/- .25 psi
T53 Pt1
0
____________
____________
____________
T55 Pt1
10
____________
____________
____________
T63 Pt1
20
____________
____________
____________
L714 PTBM
30
____________
____________
____________
40
____________
____________
____________
50
____________
____________
____________
R-cal
____________
Transducer: T39
Hardware Name: HL20
188