TB 1-4920-443-35
Alignment Description. TI parameters and performance specifications which pertain to this alignment are listed
TI Characteristics
Performance Specifications
Test Method
Range : 0 to 100 amps Tolerance 1% FS
Functional Test
Range : 0 to 300 VV AC Tolerance 1% FS
Functional Test
Range : 0 to 50 amps Tolerance 1% FS
Functional Test.
Range : 0 to 50 VV DC Tolerance 1% FS
Functional Test
Digital Flow Indicator
Ranges: 380 to 5700 PPH (oil)
Must be calibrated at a qualified
and Turbine Flowmeter
190 to 2280 PPH (fuel)
lab.
95 to 950 PPH (fuel)
7.6 to 494 PPH (fuel)
Tolerance: 0.35% of indication
Digital Stop Clocks
Range: 0 to 9999.99 Sec, 0 to 9999.99 Min
Alignment is not required.
Dyno Shroud Position
Range: 0 to 100% (0-16 V dc)
Precision Voltage Source
Indicator
Tolerance 0.2%
Frequency Meter
Range: 55 to 65 Hz Tolerance 2%
Functional Test.
Fuel Level Gage
Range: 0 to 100%
Alignment is not required
Limit Control
Range : 0 to 1300 F, Tolerance: 3 counts
Thermocouple Voltage Source
Temperature
Pressure Indicator
Range: Various, Tolerance: 2 counts
Precision Voltage Source
Pressure Transducers
Range: Various, Tolerance: 0.5%
Pressure Alignment Test Sets
Specific Gravity
Ranges: 0.680 to 0.850 specific gravity
Tested by comparison with a
Indicator
Tolerance: 1% of range
standard hydrometer.
Speed measurement
Range: 0 to 120% Analog: 0.2% FS
System
Digital: 0.2% FS
proportional to verified rotation
rate.
T53 Inlet Guide Vane
Range: -10 to 90 degrees
Precision Voltage Source
(IGV) Position
Tolerance .2 degrees
(same as T700 IGV)
T53/T55/T63 TA Position
Range: 0 to 150 degrees
Precision Voltage Source
Tolerance .5 degrees
(Same as PAS)
T53/T55/T63 Torque
Range IN-LBS Tolerance: 0.4% FS, Mod:
BF Goodrich box, digital
Measurement System
22793
Range: 0-600 FT-LBS, Tolerance: 5 counts
Hanging Weights
T700 Inlet Guide Vane
Range: -10 to 90 degrees (0-8V8V dc)
Precision Voltage Source
(IGV) Position
Tolerance .2 degrees
T700 Load Demand
Range: -45 to 105 degrees (0-12V12V dc)
Precision Voltage Source
Spindle (LDS) Position
Tolerance .5 degrees
T700 Power Available
Range: 0 to 150 degrees (0-12V12V dc)
Precision Voltage Source
Spindle (PAS) Position
Tolerance .5 degrees
Range : 0-600 FT-LBS, Tolerance: 5 FT-LBS
Precision Voltage Source
Temperature
Range : 0 to 1300 F 0 to 2000 F Tolerance:
Thermocouple Calibrator
Measurement System
Analog: 0.1% FS Digital: 1 count
Variable Filter
Range: 8 to 2500 Hz Tolerance: 1%
proportional in amplitude &
frequency response.
Vibration Meter
Displacement Range:
0 to 150 mils peak to peak from 5 to 5000 Hz
proportional in amplitude and
Velocity Range: 0 to 150 in/sec from 5 to 5000
frequency to meter deflections.
Hz
Vibration Transducers
Range: 50 to 150 mV/in/sec (sensitivity)
Must be calibrated at a qualified
lab.