TM 5-6675-328-14
f.
Holding it taut, apply tape perpendicular to panel skin. Do not apply with rolling motion either end-to-end or
center-to-ends. Do not rub each strip in place individually. Apply all strips lightly with proper overlap and rub
into place.
g.
If necessary, damaged tape can be replaced; however, it should be removed with careful peeling motion to
avoid damage to sealant. If sealant also peels back, new sealant should be applied. Complete removal of old
sealant is not necessary. Permanent repair by direct support, or higher level of maintenance, should be made
as soon as possible.
1-16.14
Replace Tiedown Socket.
MOS:
41B, Topographic Instrument Repair Specialist
or
83FJ6, Reproduction Equipment Repairer
TOOLS:
Cross Tip Screwdriver
Flat Tip Screwdriver
SUPPLIES:
Tiedown Socket
a.
Remove screws from tiedown socket.
b.
Pry defective socket from floor.
c.
Install new tiedown socket. Rotate new tiedown socket enough to avoid installing screws in old screw holes.
d.
Reinstall screws.