TM 5-6675-328-14
a.
Drill pop rivets from hinged cover to remove vent cover.
b.
Remove defective vent cover and transfer mounted hardware to new cover.
WARNING
Dry cleaning solvent, P-D-680, used to clean parts is potentially dangerous to
personnel and property. Avoid repeated and prolonged skin contact. Wear solvent-
impermeable gloves and eye/face protective equipment when using solvent. Do not
use near open flame or excessive heat. Flash point of solvent is 100° F to 138 F
(38 C to 59° C).
Fumes and chemicals used may result in death or blindness if personnel do not use
proper ventilation.
c.
Scrape gasket off van body and clean area with solvent.
d.
Secure new gasket to section with adhesive.
e.
Aline ventilation fan vent cover and pop rivet to hinge.
f.
Check cover for tightness of closure.
1-77