TM 5-6675-328-14
Table 1-2. TROUBLESHOOTING - Cont
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
2. NO ELECTRICAL POWER TO EQUIPMENT - Cont
Step 3. Check circuit breaker output for 120 V ac.
(a)
If output voltage is present, proceed to step 4.
(b)
If output voltage is not present, replace circuit breaker (paragraph 1-20.5).
Step 4. Remove receptacle and check for 120 V ac input.
(a)
If present, replace receptacle (paragraph 1-16.6).
(b)
If not present, repair or replace defective wiring.
1-47