TM 5-6675-328-14
Table 10-1. OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES - Cont
B - Before
W - Weekly
AN - Annually
(Number) - Hundreds of Hours
D - During
M - Monthly
S - Semiannually
A - After
Q - Quarterly
BI - Biennially
ITEM TO BE INSPECTED
For Readiness
ITEM
IN-
Reporting,
NO.
TER-
Equipment Is
VAL
PROCEDURE
Not Ready/
Available If:
SUPPORT ITEMS Cont
9
B
Inspect Battery Box Cont
2.
Check all connections.
Damaged or
corroded
connections.
3.
Inspect in-circuit and batteries for loose or dirty contacts, damage,
Damaged or
leakage, or corrosion.
corroded contacts.
4.
Inspect for presence of spare bulbs.
5.
Inspect cables for broken or frayed wires and loose or defective plugs.
Defective
wiring or plugs.
6.
Inspect hand lamp for defective wiring, cracked or
Defective wiring,
broken casing, and defective terminal plug or lamp.
plug, or broken
casing.
7.
Be sure hand lamp switch operates properly.
Defective switch.
10-17