TM 5-6675-328-14
Table 1-1. OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES - Cont
B - Before
W - Weekly
AN - Annually
(Number)-Hundreds of Hours
D - During
M - Monthly
S - Semiannually
A - After
Q - Quarterly
BI - Biennially
ITEM TO BE INSPECTED
For Readiness
ITEM
IN-
Reporting,
NO.
TER-
Equipment Is
VAL
PROCEDURE
Not Ready/
Available If:
VAN BODY - Cont
2
Inspect Interior - Cont
d.
Inspect contents for damage. Then use checklist
to inventory contents.
e.
Replace damaged or missing items.
f.
Repack kit.
g.
Reinstall kit.
B/W
12. Inspect blackout curtains.
a.
Inspect blackout curtains and valances for
Curtains
tears, missing hooks, or broken eyelets.
damaged.
b.
Inspect nylon hook tape on curtain and wall for
security of attachment.
3
B
Insect Air Conditioner/Heater. Refer to TM 5-4120-
367-14 for preventive maintenance checks and services.
4
M
Service Power Cable.
WARNING
Electrical shock hazard. Power must
be deenergized before servicing cable.
Death or serious injury can result
from failure to observe this safety
precaution.
a.
Turn off safety switch.
b.
Disconnect cable from power entry panel.
c.
Wrap any cuts or abrasions in cable with
electrical insulation tape.
d.
Reconnect power cable to entry panel.
1-23