5-16.6. Replace Controller.
MOS:
41B, Topographic Instrument Repair Specialist
TOOLS:
Flat Tip Screwdriver
Hex Head Key Wrench Set
3/8 in. Combination Wrench
SUPPLIES:
Controller
WARNING
Death or serious injury may occur from electrical shock unless power cord is unplugged before servicing.
a.
Unplug power cord.
b.
Remove cover, tag motor connections, and disconnect motor power cord.
c.
Loosen setscrew on controller mounting bracket and remove controller.
d.
Install new controller and tighten setscrew.
e.
Connect new controller wires to motor connections, remove tags, and reinstall cover.