TM 5-6675-328-14
INDEX
PROCEDURE
PARAGRAPH
Replace Toggle Switch or Rheostat ..............................................................................................
2-20.1
Replace Transformer . ..................................................................................................................
2-20.2
Replace Motor(s)...........................................................................................................................
2-20.3
Remove/Install Optical Plummet Collimator . ................................................................................
2-20.4
Remove/Install Short-Range Optical Calibrator ............................................................................
2-20.5
2-20.1 Replace Toggle Switch or Rheostat.
MOS: 41B, Topographic Instrument Repair Specialist
TOOLS: Hex Head Key Wrench Set
Soldering Iron
Flat Tip Screwdriver
5/16 in. Combination Wrench
9/16 in. Combination Wrench
SUPPLIES: Toggle Switch
Rheostat
Rosin Core Solder (Item 20, Appendix E)
WARNING
Death or serious injury from electrical shock may occur unless power cord is unplugged
before servicing equipment.
a. Unplug power cord.
2-67