TM5-6675-326-14
6-9.1 Replace Battery Pack - Continued
CAUTION
Arrows on ribbon cable and calculator must
a l i n e .
Damage to calculator can result if
cable is plugged in backwards.
c . T u r n c a l c u l a t o r o v e r . R e p l a c e r i b b o n c a b l e.
d .
Reconnect power transformer to wall outlet. Turn calculator
ON.
6-9.2 Replace Teflon Guide Washer
PERSONNEL REQUIRED:
1 Terrain analyst MOS 81Q
TOOLS:
3 / 1 6 - i n . f l a t - t i p s c r e w d r i v e r
S t e e l k n i f e
3/32-in. socket-head screw key
MATERIALS/PARTS :
Teflon guide washer
General purpose glue (item
, appendix E)
Technical acetone (item
, appendix E)
REMOVAL:
CAUTION
Hold tracer arm with one hand before removing
l e n s t r a c i n g a s s e m b l y . T r a c e r a r m w i l l f a l l
and damage planimeter.
a.
Remove lens tracing assembly from planimeter tracer arm by
loosening setscrew on top.
Slide lens tracing assembly off
tracer arm.
6-143