TM5-6675-326-14
6-6.2.4 Mounting Tracer Arm Extension Assembly - Continued
NOTE
Different tracer arm lengths with same tracer arm
can be obtained by loosening two thumbscrews and
s l i d i n g t r a c e r a r m I n a n d o u t o f i t s s l o t .
T r a c e r
arm lengths should be premarked short, medium, and
long.
If any other tracer arm length is desired,
planimeter must be realined.
e. Tighten two thumbscrews to secure tracer arm extension. Be
sure lens tracing assembly is flat on table surface.
f .
Readjust encoder and remote tracer switch wires through
antenna.
6-6.2.5 Mounting Needle Tracing Assembly
a. Remove remote tracer switch from lens tracing assembly.
CAUTION
Hold tracer arm while removing lens tracing
assembly.
P l a n i m e t e r w i l l t u r n o n i t s s i d e.
Damage to planimeter disk can result.
b .
Loosen setscrew.
Sliding lens tracing assembly from tracer
arm,
remove.
6-41