TMS-6675-326-14
4-14.1 Replace Power Switch
PERSONNEL REQUIRED:
1 Topographic instrument repair specialist MOS 41B
TOOLS: 9/64-inch flat-tip screwdriver
S t r a i g h t - n o s e p l i e rs
MATERIALS/PARTS:
Power switch
REMOVAL:
WARNING
ELECTRICAL SHOCK
Unplug power cord before servicing the
zoom transfer scope.
Failure to do so
may result in death or serious injury.
a. Turn power OFF, and unplug power cord.
b .
Unplug below-stage illuminator cord.
c. Remove fuse caps and fuses.
d.
Remove six screws from cover on underside of crosspiece
assembly. Move cover to allow access to power switch.
4-34