TM 5-6675-325-14
d.
Disconnect wires from defective switch.
e.
Connect wires to new switch.
f. Install switch and secure with nut.
g.
Adjust striker plate until plate contacts rollers.
h. Reinstall conduit cover.
i.
Turn on circuit breaker.
1-16.6 Replace Receptacle.
MOS : 83FJ6, Reproduction Equipment Repairer
or
41B, Topographic Instrument Repair Specialist
TOOLS:
Flat Tip Screwdriver
SUPPLIES: Receptacle
W A R N I N G
Death or serious injury may occur if receptacle circuit breaker is not turned
off before working on receptacle.
a.
Turn off receptacle circuit breaker.
b. Remove cover plate screws.
1-70