9-16.11 Remove/Install Diazo Support Cabinet.
MOS: 83FJ6, Reproduction Equipment Repairer
PERSONNEL: Two persons are required to perform this procedure.
TOOLS: Drill and Bits
9/16 in. Combination Wrench
7/16 in. Combination Wrench
1-1/8 in. Socket, 1/2 in. Drive
3 in. Extension, 1/2 in. Drive
SUPPLIES: Tape
Diazo Support Cabinet
Remove Diazo supplies from cabinet.
Check that all ammonia and absorber
a.
containers are securely capped.
b. Unplug Diazo copier. Coil and tape cord.
c.
Pull away tubing from cabinet into Diazo and tape to Diazo copier.
d. Remove mounting bolts and washers, then remove Diazo copier.
e.
Remove Diazo copier mounting plate from top of cabinet by removing
bolts, washers, and nuts.
f. Remove portable tracing/scribing boards from mounting bracket.
Remove portable tracing/scribing board mounting bracket from Diazo
g.
h. Remove bolts and washers from angle brackets. Then remove cabinet.